I was asked to do a roof inspection and a report on this roof in London, I was told that the roof was soft underfoot and that they didn't know why. When I got on the roof and started to walk around, I was able to establish many different defects in the way that the GRP glass-reinforced plastic roof had been installed; flashings were compromising the drip detail on the cavity walls and generally the GRP had not been installed very well. I could only do a visual inspection and couldn't cut any holes in the roof however we because the roof was so soft underfoot I could f...
Просмотров: 983

Видео

One or Two layers of PIR insulation in a warm roof?
Просмотров 4,6 тыс.4 часа назад
Always phone or email with photos if you need help or advise Steven Dickinson London Flat Roofing 07802300099 info@londonflatroofing.co.uk One or two layers of PIR insulation is the question nobody seems to be talking about, so in this video, I express my opinions on the subject. This particular viewer sent over some information and asked the question. He also posed the question of whether or n...
Warm roofs, the biggest mistake I see when doing a roof inspection.
Просмотров 168 тыс.4 месяца назад
Alway phone or email if you need help or advise Steven Dickinson London Flat Roofing 07802300099 info@londonflatroofing.co.uk Nobody tucks in their warm roofs! What do I mean? If you bought a new quilt for your bed and you laid down under it but didn't tuck it in around the edges, you would get cold. Same for when you're doing a warm roof, you have to extend the insulation down to the next ther...
Home Buyers Beware: Roof Condition Report Reveals All
Просмотров 4,8 тыс.5 месяцев назад
Steven Dickinson London Flat Roofing 07802300099 info@londonflatroofing.co.uk Over the years, I have been doing more and more surveys on roofs, and this survey was for a homebuyer's roof condition report . The customer had already had a Royal Institute of Chartered Surveyors RICS house buyers report undertaken. However, the RICS surveyor didn't have equipment to get access up onto the top roof ...
Game-Changing Artificial Roof Slates
Просмотров 95 тыс.6 месяцев назад
Game-Changing Artificial Roof Slates
Best way to add cold roof venting when its been missed on a flat roof.
Просмотров 9 тыс.7 месяцев назад
Best way to add cold roof venting when its been missed on a flat roof.
Warm Roof Firrings where do they go? Your Questions Answered
Просмотров 14 тыс.7 месяцев назад
Warm Roof Firrings where do they go? Your Questions Answered
Warm roof vapour barrier gives temporary protection
Просмотров 6 тыс.7 месяцев назад
Warm roof vapour barrier gives temporary protection
The Hidden Dangers of Mould: Exposing High Humidity & No Ventilation
Просмотров 9 тыс.Год назад
The Hidden Dangers of Mould: Exposing High Humidity & No Ventilation
Condensation In the loft things not to do
Просмотров 48 тыс.Год назад
Condensation In the loft things not to do
Survey of a new tiled roof.
Просмотров 7 тыс.2 года назад
Survey of a new tiled roof.
Vapour Barrier Installed Correctly - Walls and Cold Roofs
Просмотров 91 тыс.2 года назад
Vapour Barrier Installed Correctly - Walls and Cold Roofs
Badly fitted insulation between joists and thermal imaging
Просмотров 214 тыс.2 года назад
Badly fitted insulation between joists and thermal imaging
Noisy Banging Flat Roof Problems
Просмотров 17 тыс.2 года назад
Noisy Banging Flat Roof Problems
Through Ventilation Cross Ventilation Explained
Просмотров 44 тыс.2 года назад
Through Ventilation Cross Ventilation Explained
How to fit downlight in flat roofs
Просмотров 41 тыс.2 года назад
How to fit downlight in flat roofs
Vapour barriers for roofs and walls explained
Просмотров 101 тыс.2 года назад
Vapour barriers for roofs and walls explained
New Build Passive House Roof Leaking or Sweating?
Просмотров 49 тыс.2 года назад
New Build Passive House Roof Leaking or Sweating?
Condensation/Sweating on garden office roof
Просмотров 113 тыс.2 года назад
Condensation/Sweating on garden office roof
Leaking new warm flat roof problems
Просмотров 41 тыс.2 года назад
Leaking new warm flat roof problems
Flat Roof Insulation, Bad Storage and Gluing Down!
Просмотров 15 тыс.2 года назад
Flat Roof Insulation, Bad Storage and Gluing Down!
Electronic flat roof leak detection Testing a leaking roof Roof surveys
Просмотров 22 тыс.2 года назад
Electronic flat roof leak detection Testing a leaking roof Roof surveys
Sweating and Wet Parapet Wall, Cavity Wall Insulation
Просмотров 194 тыс.2 года назад
Sweating and Wet Parapet Wall, Cavity Wall Insulation
Garden room, Office in the garden, Mancave Vapour control in the roof and walls.
Просмотров 30 тыс.3 года назад
Garden room, Office in the garden, Mancave Vapour control in the roof and walls.
Can I save my sweating cold flat roof with no vapour barrier ?
Просмотров 75 тыс.3 года назад
Can I save my sweating cold flat roof with no vapour barrier ?
Ventilation Cold flat roofs Abutment vents Making V purchasing them?
Просмотров 39 тыс.3 года назад
Ventilation Cold flat roofs Abutment vents Making V purchasing them?
Hybrid roofs explained Flat roofs Warm and Cold
Просмотров 168 тыс.3 года назад
Hybrid roofs explained Flat roofs Warm and Cold
Venting a cold roof view asks for help
Просмотров 68 тыс.3 года назад
Venting a cold roof view asks for help
Alutrix 600 is there a cheaper vapour control layer?
Просмотров 31 тыс.4 года назад
Alutrix 600 is there a cheaper vapour control layer?
Warm flat roof two layers of insulation will it work?
Просмотров 49 тыс.4 года назад
Warm flat roof two layers of insulation will it work?

Комментарии

  • @paulfaulkner4488
    @paulfaulkner4488 Минуту назад

    You are mentioning a vapour barrier just use the right insulation with a multi foil

  • @dominicjohnson8427
    @dominicjohnson8427 2 часа назад

    Is the air vapour control layer simply dpm or is there a particular brand normally used ?

  • @philipoakley5498
    @philipoakley5498 7 часов назад

    The "if" part of a two layer construction (rather than single layer) is whether sufficient moisture could accumulate at the layer join for it to actually condense out and then propagate the potential mould/rot. The solid PIR has nowhere for there to be that condensable moisture (compare with mineral wool etc). It's a long slow game (decade of life) to ensure that the moisture doesn't have opportunities to ruin everything. So many things to consider!

  • @dwainDigital
    @dwainDigital 11 часов назад

    So how'd you resolve the cold area around the outside if you make it a warm roof on a roof like that?

  • @mmroofs
    @mmroofs 20 часов назад

    Hi Steve, I sincerely appreciate your videos. You specialize in a crucial area of the roofing industry by addressing moisture-related issues. There's a significant need for education in this aspect of our field.

  • @marconst10
    @marconst10 21 час назад

    This guy s a Legend!

  • @9111logic
    @9111logic 22 часа назад

    Thanks for sharing 🙏

  • @eddjordan2399
    @eddjordan2399 22 часа назад

    i hate glass fiber roofs just use epdm easy super strong essay to joint never had a problem with them. glass fiber way to many variables Keep up the good work Steve..

    • @peteramberley9952
      @peteramberley9952 22 часа назад

      That's because people don't lay them properly. You don't get many boats made out of epdm.

    • @SteveRoofer
      @SteveRoofer 21 час назад

      You also dont get many boats made out of GRP that are laid up outside in uncontrolled endearments

    • @SteveRoofer
      @SteveRoofer 21 час назад

      Yes I love EPDM also

    • @redline589
      @redline589 21 час назад

      Both have their benefits, but what's more important is how well they are constructed.

    • @northeastcorals
      @northeastcorals 14 часов назад

      @@redline589 Yeh I've installed both types on my property (both DIY) & think both have their pros & cons IMO. For my small roof with lots of complicated shapes like several kerbs for roof windows etc GRP was a better option in my own opinion. I used EPDM for my other roof which is a simple large flat roof with only 2 flat/low profile windows on it.

  • @smellypunks
    @smellypunks День назад

    Can you do a video about insulating solid walls (i.e. no cavity) and the issues around interstitial condensation, air gap or not, breathable insulation or not etc. There are millions of homes in the UK that have solid walls and would be good to hear from you on the subject if you can speak to it?

    • @SteveRoofer
      @SteveRoofer День назад

      Ill put that on my list of video to do

  • @northeastcorals
    @northeastcorals День назад

    I could be wrong but I think I can spot some black plastic sheeting just say sticking up out of the 1st insulation layer at the corner after the window & the top right corner which may have been used as the vapour control layer. I'm not saying that would be correct, just pointing out what I think I can see.

    • @SteveRoofer
      @SteveRoofer День назад

      You could be right; however, plastic is the wrong material to use on a warm roof. Additionally, plastic Air Vapour Control Layers (AVCL) are typically green. Black is normally the color used for Damp Proof Course (DPC) or Damp Proof Membranes (DPM), all of which do not use virgin plastic and therefore do not offer the correct vapor resistance.

  • @SuperMickjr
    @SuperMickjr 2 дня назад

    Is this a cash job ?

    • @SteveRoofer
      @SteveRoofer 2 дня назад

      I don't understand what you mean

  • @user-uk4se5jp1s
    @user-uk4se5jp1s 2 дня назад

    I would guess that you would say the existing felt is a bad AVCL when converting an uninsulated roof to a warm roof. My bungalow had a secong floor with dormers added and flat roof extension 18 years ago. Not a scrap of insulation anywhere. Expensive to heat in the winter and an oven in the summer. At least th electrician was good out i would be much more concerned.

    • @SteveRoofer
      @SteveRoofer 2 дня назад

      no the existing roof can make a very good air vapour controller because the problem is tucking the roofing around the edge which was the subject of my last video. You've gotta make sure that you tuck it in around the edge. Bring the thermal element of the insulation that's gonna go over the top of the roof down to the next thermal element which is the wall this is so often missed and therefore realistically you're losing 7080% of the performance of the roof by not doing it

  • @MrKarlPrince
    @MrKarlPrince 2 дня назад

    As well over overlapping joints reducing leakage, other advantages of multiple layers: less bowing (especially after cutting) and easier to cut, especially around corners and protrusions.

    • @SteveRoofer
      @SteveRoofer 2 дня назад

      Yes, all of the above are also good advantages

  • @ricos1497
    @ricos1497 2 дня назад

    Interesting video. What would you recommend instead of the plywood against the internal wall?

    • @SteveRoofer
      @SteveRoofer 2 дня назад

      the Air Vapour Control Layer (AVCL) gos up against the wall then the insulation

    • @ricos1497
      @ricos1497 2 дня назад

      @@SteveRoofer makes sense, thanks

  • @dickdastardly5534
    @dickdastardly5534 2 дня назад

    I am thinking of putting solar on my 3 bedroom semi detached simple pitched roof, the roof is the original build and I was wondering would it be wise to change the roof first or not bother as its still functioning - I appreciate this is a bit of a difficult question without seeing the roof (about 50 years old) ut would appreciate your thoughts on the matter thanks 👍🏻

  • @adamkingdon8063
    @adamkingdon8063 2 дня назад

    It certainly has to be a warm roof when it’s located in Scotland, do you ever work up that way or are you just looking for work in London? I can possibly put you in touch with a roofer that also specialises in water damage etc that you could liase with he lives up that way.

    • @SteveRoofer
      @SteveRoofer 2 дня назад

      Thanks for the offer, but we're London-based in really don't get any work up there

  • @ciarankavanagh9424
    @ciarankavanagh9424 2 дня назад

    Those plastic polypropylene slates aren't good. They are amazing to use, all the same thickness, look great, lightweight. So quick and easy to use. They tick loads of boxes until you see them 2/ 3 years after you've put them on. They fade terribly like all plastic materials. The wrong client will pursue you if they are very particular

  • @billfromgermany
    @billfromgermany 4 дня назад

    I installed 142 mm alufoil-faced insulation for my workshop build. The external sheeting was already completed, so I had real problems getting a precisely cut sheet into the stud gaps. Effectively, the sheet was compressing air. I found the most effective way to get a good seal was to cut the sheet exactly 10 mm too small, insert the sheet, then fill the gap with foam, starting from the back of the space. Of course, a workshop doesn’t have the insulation and damp requirements of a house, but I wonder wonder if my solution would be acceptable for habitable spaces. Final point, I bought the Festool specialist insulation saw. Used with their track it enabled extremely accurate and square cuts in the insulation. Disgracefully expensive though!

  • @andreicotorobai731
    @andreicotorobai731 4 дня назад

    Hi Steve , could i ask what type of vapor barrier to use for warm flat roof and where to buy ? thanks

  • @andypag1071
    @andypag1071 4 дня назад

    Is this the same as a warm pitched tiled roof? Does the foam insulation carry a lateral component of the weight of the tiles?

  • @christopherhook6789
    @christopherhook6789 5 дней назад

    Buy cheap labour ...albania ? , get this outcome.

  • @seanbriggs
    @seanbriggs 8 дней назад

    Counter batten underneath 🤷‍♂️

  • @andreicotorobai731
    @andreicotorobai731 9 дней назад

    thanks for video , how to do if joists are fixed on wall hangers inside the building? is a cold roof , bcz of building hight ..thanks

  • @davidrobinson1746
    @davidrobinson1746 9 дней назад

    Hi - I’m just designing my warm roof solution for an existing flat roof, thanks for your videos they are really informative. I intend to use Alutrix 600 but wanted to ask about it securing to a concrete slab roof - would you use any primer or additional adhesive Also what mechanical fittings would you recommend for securing the new insulation and osb to the concrete slab Thanks in advance

  • @andreicotorobai731
    @andreicotorobai731 15 дней назад

    hi , thanks for video ! planning my new roof , same cold roof , joists hanging on the wall with hangers , got the walls from sides .. need ventilation! how is better to do .. go battens along the joists then across the joists ? need 2 layers of battens or one ?! thank you

  • @momalik5934
    @momalik5934 15 дней назад

    Great vid 1 question comes to mind like a cold roof does a warm roof require 50mm of ventilation?

  • @brandonSpivey-vx4eu
    @brandonSpivey-vx4eu 16 дней назад

    Whats the name of these tiles you recommend

  • @BilbosBrother
    @BilbosBrother 16 дней назад

    How does the cross battening work with furrings on a flat roof with a sky light?

  • @micksoden7064
    @micksoden7064 19 дней назад

    Have polymer plastic slates on our new build house for 18 years.they look great,as good as new,and have withstood 120 km per hour winds.

  • @michaelbrooks3859
    @michaelbrooks3859 20 дней назад

    Only problem is when they fade

  • @girlatendofrwjishot
    @girlatendofrwjishot 21 день назад

    My roofing company in Utah, USA couldn't find anything decent on the market so we've begun using perforated metal z-bar and a custom bent-counter flashing which cleats into the z-bar. Very cost-effective, readily available materials without too much fabrication needed, and it's all metal, holds together very nicely, feels solid, and flashes into headwall same as any other counter flashing.

  • @Seqhael
    @Seqhael 21 день назад

    Hello Steve, I’m a carpenter new to the UK from NZ where our insulation regs are a lot different. I’m doing my first build here for a client, and the original plan was a pitched roof extension with cold roof insulation. The pitched ceiling has now changed to a flat ceiling but still a pitched roof. Am I better off insulating the flat ceiling, or the pitched roof?

  • @tiredgunnersaurus
    @tiredgunnersaurus 22 дня назад

    Thanks for the video. We have a very similar bacony that recently was painted with fiber glass and keeps cracking. Do you still recommend Hydrostop EU AH-25 6 years on?

  • @maireadrussell8475
    @maireadrussell8475 22 дня назад

    They are spaced the same regardless. Either between joists or straddling them. Or is it just me?

  • @paulhampson8496
    @paulhampson8496 24 дня назад

    I've used them super slate the 1s I used art slate something like that nice clean work when working with them

  • @freesaxon6835
    @freesaxon6835 25 дней назад

    Whats the liquid rubber called ?

  • @davidgarofalo3800
    @davidgarofalo3800 25 дней назад

    Hi, how many screws per sheet of insulation would you use? I'm doing a flat roof soon with Resitrix, 130mm insulation and Alutrix. The architect doesn't want another layer of plywood on top on the insulation before the Resitrix. Thank you.

  • @stephenknox9242
    @stephenknox9242 27 дней назад

    Is glasswool or rock wool better for a cold roof because it’s more breathable ?

  • @biccypequeno
    @biccypequeno 28 дней назад

    Hey Steve Roofer. Can I ask you a question here? I've built a summerhouse in the garden and haven't thought about venting anything until I recently saw your videos. It's framed with 100x50mm pressure treated timber. Whilst I could vent the roof without too much hassle venting the wall cavities is going to be a challenge. The outside walls are UPVC cladding over a polythene sheet and the roof is epdm. So there's not much scope for water to move out if it gets trapped in the walls. It's a dilema and i just asked ChatGPT what he thought and he suggested using closed cell spray foam insulation which means i don't need to worry about venting anything as the foam is a vapour barrier and completely impermiable and there will be no gaps for air or moisture to move across. What say you?

  • @bapoo
    @bapoo 29 дней назад

    All i’d add is the first one, he’s making a PIR sandwich with the 25mm on top. Should be the other way around as the dew point is pushed further out so any gaps in the expanding foam will be somewhere for interstitial condensation to form. Small risk and low volumes but easily eliminated if reversed.

  • @SunofYork
    @SunofYork 29 дней назад

    I love Steve;s hair...It is strong and thick and looks good and won't come off in a gale, though it will lighten in the sun. . Mine is flimsy and thinning even though I am only 76. Envious !

  • @allysoncipollone890
    @allysoncipollone890 Месяц назад

    I have a room that i think was a patio that the previous owner closed in. I dont think there is any ventilation and im not sure what to do 😅

  • @damdamdam8346
    @damdamdam8346 Месяц назад

    Everyday is a school day - thanks for the video....

  • @damdamdam8346
    @damdamdam8346 Месяц назад

    fab thanks for the direction

  • @pillarsofdoom4891
    @pillarsofdoom4891 Месяц назад

    But what about cold roof?

  • @aarontpassmore
    @aarontpassmore Месяц назад

    plastic roofing

  • @gerarddowling2089
    @gerarddowling2089 Месяц назад

    Hi Steve build a new house with a warm flat rood , 9x2 under furring 6 inch to 1 inch 18 mm osb aletrex 600 vapor barrier 150 insulation 18mm osb with termal broking fixings resetrix rubber . on under side of roof higest side 15 in lowest side 10 in i am putting a air tightnes membrane before plasterboatd , all of the walls are tucked in and seealed eg insulation from cavity meets roof insulation . question with no air ventalition under roof will it cause a problem

  • @joecurran
    @joecurran Месяц назад

    Timber need Air don't forget that when insulating your home.

  • @joefanningartist
    @joefanningartist Месяц назад

    What happens when you screw the drywall it's going to make a whole in the vapour barrier?

  • @joefanningartist
    @joefanningartist Месяц назад

    Great video, in construction years and membranes can be so confusing. What I've taken from this, is do the proper research if you want to a good job. For vapour barrier membrane AIR TIGHTNESS is key, that's why they give you the tapes with it.